Skip to content

Archive · Analysis

Analysisworked & checked

Thermodynamics, Heat Transfer, Fluid Mechanics, and Aerospace Dynamics. Worked problems with every number traced, and every source error flagged.

Ceilings And Time To Climb: Integrating 1/ROCh_s = 24,737 ftt = ∫ dh / ROC(h)ROC
AnalysisAerospace

Ceilings And Time To Climb: Integrating 1/ROC

Service ceiling at 24,737 ft, an extrapolated absolute ceiling, a jet table that never reaches either, and why low-ROC altitudes dominate climb time.

9 min

All worked problems

Climb And Glide: Optimum Speeds From Excess Powerslope = ROC/V = sin γV (ft/s)ROC = (P_A − DV)/W
AnalysisAerospace

Climb And Glide: Optimum Speeds From Excess Power

Maximum rate is not maximum angle, best glide is not minimum sink — and an audit of which source numbers can be reproduced.

10 min
From A Physical Truss To [K]{d}: The Direct-Stiffness Pipelineσ₉ = −16.8 MPa[K]{d} = {F}30°
AnalysisFinite Element Analysis

From A Physical Truss To [K]{d}: The Direct-Stiffness Pipeline

Six nodes, nine bars, an inclined roller at 30°, and every step from bar element to member stress — with the missing geometry reconstructed from equilibrium.

11 min
When Bending Is Not Enough: Euler–Bernoulli Versus Timoshenkoq = 2400 lbf/in L/h = 5Δ_TB = Δ_b + qL²/8k_sGAEB −9.1%
AnalysisFinite Element Analysis

When Bending Is Not Enough: Euler–Bernoulli Versus Timoshenko

A stocky L/h = 5 beam where shear flexibility adds 0.00467 in of sag and Euler–Bernoulli underpredicts by about 9.1%.

9 min
From Continuum To Mesh: Plane Stress And The Patch Testt∫BᵀDB dAσx = 7.0 MPaεx = 1e-4 F = 35 kN
AnalysisFinite Element Analysis

From Continuum To Mesh: Plane Stress And The Patch Test

Constitutive matrices, BᵀDB, CST versus Q4, and a patch test that must return 7 MPa and 35 kN on every mesh.

10 min
Does A 700 W Copper Plate Pass ASME B31.3?U∞, T∞h_x ∝ x^-1/2δ(x)q″ = 700 W · T_s ≈ 277 °C > 260 °C
AnalysisHeat Transfer

Does A 700 W Copper Plate Pass ASME B31.3?

Integrating a singular local h_x into an average, then Newton's law: 277 °C against a 260 °C limit.

6 min
The Thermal Window: Two Convection Systems, One Energy BalanceROOM 20 °COUTSIDE −10 °CL = 20 mmT₂ ≈ 3.9 °CRa_L, Nu
AnalysisNatural Convection

The Thermal Window: Two Convection Systems, One Energy Balance

Room-side buoyancy and a 20 mm air gap coupled at steady state to find a 3.9 °C outer pane — with an honest look at the correlation's range.

9 min
Radiative Geometry: View Factors And A Black-Disk BalanceA₁ T₁A₂ T₂ ≈ 339 KF₁₂ ≈ 0.38surroundingsA₁F₁₂ = A₂F₂₁ ΣF = 1
AnalysisRadiation

Radiative Geometry: View Factors And A Black-Disk Balance

Reciprocity, summation, and why the source's 394 K answer should read 339 K.

8 min
Inside The Condenser: From Latent Heat To Water VelocitySTEAM · h_fg · 1.4 MW7 tubes · ΔT_lm 26.65 K · V ≈ 1.79 m/s
AnalysisHeat Exchangers

Inside The Condenser: From Latent Heat To Water Velocity

Seven tubes, 1.4 MW of condensing steam, an LMTD of 26.65 K, and 1.79 m/s of cooling water.

7 min