Heat Transfer
Does A 700 W Copper Plate Pass ASME B31.3?
Integrating a singular local h_x into an average, then Newton's law: 277 °C against a 260 °C limit.
Explorer · Local versus average h
Average h̄
2.72 W/m²K
Surface Tₛ
277.4 °C
ASME 260 °C
Fails
Margin
-17.4 K
Problem
An ASTM B152 copper plate with length and area dissipates into air at . The local convection coefficient falls along the plate as
Find the average coefficient , the surface temperature , and whether the plate stays under the limit that ASME B31.3 lists for ASTM B152 copper.
| Quantity | Value |
|---|---|
| Plate length | 1 m |
| Plate area | 1 m² |
| Heat dissipated | 700 W |
| Air temperature | 20 °C |
| Code limit | 260 °C |
Assumptions: steady state, uniform surface temperature, constant air properties, and the supplied laminar-style correlation.
Equation Chain
The order matters: average first, then Newton's law of cooling, then the code check.
Three tempting shortcuts are wrong. The midpoint value is not the average of a nonlinear profile. The end value is the minimum, because decreases with . A trapezoidal average fails outright since at the leading edge.
Average Coefficient
The singularity at is integrable:
Dropping the factor of 2 from gives , which is exactly the local value at — a common slip that doubles the predicted temperature rise.
Surface Temperature
Newton's law returns a temperature difference; forgetting to add gives 257 °C and a false pass.
Code Check
The plate overshoots the limit by about 17 K. Natural or weak forced convection at simply cannot carry 700 W off one square metre while staying under the code temperature.
Why h Falls Downstream
At the leading edge the thermal boundary layer has zero thickness, so the fluid-side temperature gradient — and therefore — is largest there. As the layer thickens downstream the gradient weakens, giving for laminar flow (closer to when turbulent). This is boundary-layer growth, not a property change; properties are held constant here.
Limitations
- The surface is treated as isothermal; a real plate with a falling runs hotter downstream.
- The 260 °C value is taken from the problem statement; confirm against the current code edition before design use.
- Radiation is neglected. At 277 °C a copper surface with moderate emissivity would shed noticeable extra heat, which could change the verdict.
Verification
| Check | Result |
|---|---|
| 2.72 W/(m²·K) | |
| 277.4 °C | |
| Margin to limit | −17.4 K |
Source problem: Ch.6 Problem 6-15, ASTM B152 copper plate average and ASME compliance.